Note that you must also know the total vent piping length to select the appropriate vent pipe size. Drain fixture unit, or dfu, is a relative measure of the drain wastewater flow or load for various plumbing fixtures. Converting water supply fixture units wsfu to gallons per minute flow gpm introduction the water supply fixture unit wsfu values in this appendix are interpolated between the values listed in table 10. Accurate sizing of the domestic water heater is essential to assure an adequate supply of hot water for all fixtures at all times. Second, multiply the quantity by the number of fixture units given under either column private use or public use, whichever is applicable. One wfsu for a singel unit corresponds to one gpm, or. The conversion can only be used for one or a few fixtures. Second, multiply the quantity by the number of fixture units given under either column private use or. By adding the dfu load rating of all of the individual fixtures on a single drain to be served by a single air admittance valve aav, the plumber or designer can select an aav with sufficient capacity. The load factor for intermittent flow fixtures on water supply piping shall be computed in terms of water supply fixture units as specified in tables 382. Meters measure water either in cubic feet or gallons.
Sizing forms to aid in designing simple domestic water systems. Several factors influence distribution efficiency and can play a role in a more efficient system. Plumbing fixtures shall be constructed of approved materials, with smooth, impervious surfaces, free from defects and concealed fouling surfaces, and shall conform to. Select a fixture and rightclick and look at mvpart modify to see what i mean.
The water demand worksheet is used to determine the size and type of water meters required for your project. Drainage fixture unit dfu computation sheet fixturesource fixture units no. Supply piping would be calculated accordingly, while the total figure of the two fixture units would be used to design the drainage piping. Plumbing code of new york state 99 appendix e figure e103 examplesizing load values, in water supply fixture units wsfu cold hot total bathroom group private flush tank 2. Three steps to sizing plumbing piping systems c1s blog. Worksheet name of project information required to size water service and water distribution. The number of calculated fixture units are used to determine the minimum necessary domestic water meter size. Hp installed in nonresidential applications shall be based on the proposed use of the facility. Sizing of water piping system, 2018 plumbing code of.
A conversion table of the water demand load in fixture units to gallons per minute tabulated based on chart a 2. Im trying to figure out how many water supply fixture units wsfu can fit off of my cpvc supply lines. How does one size the plumbing line fixture units, currently the connection size is 4 these trenches will be feeding into another production sanitary line which will eventually go into a undetermined settling basin then into the the city csanitary system. Water service fixture unit calculation sheet residential. Fixture unit values for garbage disposals less than. Demand of building in wsfu converted to gallons per minute. Read chart vertically until you intersect the correct curve, then read the chart horinzontally until you read your water flow demand in g.
Each plumbing fixture end use is assigned a fixture unit value as determined by the california plumbing code. For example, the m22 manual suggests a fixture value of 35 gpm and 4. Estimate the supply demand by totaling the fixture units from the water customer demand data table fixture unit count and then by reading the corresponding ordinate from chart below. The wsfu values for typical plumbing fixtures are listed on ipc table e103. This new edition expands the ways to approach the sizing of water service lines and meters and offers improved methods for the sizing of dedicated irrigation meters. Updated load calculation list any continuous demand fixtures illinois plumbing codesection 890 appendix a, table n modified by the village of oak park development customer services department for simplicity and consistency with oak park requirements water supply fixture units wsfu for a system with flush tanks.
For fixtures not listed, the code official shall use the value of a fixture with similar flow characteristics. As the number of units increases, c decreases because the likelihood of all living units using hot water at the same time decreases. If shower head consumption is provided for, lavatories and. Drainage fixture unit dfu values heavyuse assembly other than dwelling units serving 3 or more dwelling units individual dwelling units water closet, 1. A water closet, urinal, lavatory or bidet hall not be set closer than 15 inches.
Correct sizing is contingent upon accuracy and reliability of the information applied. How do i convert water supply fixture units to gpm. First, insert the number of each type of fixture on your premises under the column headed quantity. Converting dfu drainage fixture units of a drainage system to gpm gallons per minute is a simple matter of dividing it in half. Many water demand studies have been conducted in recent years that indicate distinctly different water demand patterns. For system design and hydraulic calculations, use the fixture unit values shown in the international model codes. Pressure required at fixture to produce required flow. Read chart vertically until you intersect the correct curve, then read the chart horinzontally continue reading fixture. For continuous flow fixtures such as hose bibbs and lawn sprinkler systems, add the gallonperminute demand to the intermittent demand of fixtures. The relationship between gallons per minute gpm and fixture unit is not constant, but varies with the number of fixture units.
For example, fu is equivalent to 220 gpm, but 2000 fu is not double that, but is only 1. Chapter 4 fixtures, faucets and fixture fittings upcodes. The information necessary for sizing the building water supply and distribution systems are described in b. Fixture counts calculator residential well water treatment. Ghd discussion paper for australian building code board fixture unit rating systems, 2315402 1 june 2015 1. Click any image to enlarge water heater sizing calculations. Enter the gpm in the gpm box under design flow rate on the pump design guide. For continuous flow fixtures such as hose bibbs and lawn sprinkler systems, add the. You will need to upload water supply fixture units wsfu worksheet, plumbing plans and a riser diagram showing existing fixtures to remain, existing fixtures to be replaced and proposed fixtures in projectdox. Table o water supply fixture units wsfu for a supply system with flushometer water closets.
This fixture can only use either the tub faucet or the shower head. Ashrae modified hunter curve flow charts armstronghot water group, 221 armstrong blvd. The water supply fixture unit wfsu is defined by the american uniform plumbing code upc and is used to calculate the demand in water supply systems. Table c minimum air gaps for plumbing fixtures 890. This is the third edition of awwa manual m22, sizing water service lines and meters. Locate the type of fixtures to be used in the facility and then add up the total wsfu values for all plumbing fixtures being served. B to the degree that the increments between the wsfu listings are close enough that they do not produce. For example, a total of 120 water supply fixture units is converted to a demand of 48 gallons per minute. Sizing of water piping system icc international code council water heater section ab in determining the hot water pipe sizes. The sum total of fixture units is total fixture unit count. When many fixtures are added up the number must be. If total is 1112 fixture units, change it to 12 fixture units.
Water supply fixture units wsfu one wfsu for a singel unit corresponds to one gpm, or. Fixture unit values shown in this chart shall be used only for calculating system development charges. The assigned fixture units number assigned to each fixture is likely to be different under the ipc, but the principle is the same. This fixture has a bathtub as the basin base with a bath shower atop it and is located in private space. Static pressure loss or gain due to head is computed at 0. One of the definitions of wfu is water fixture units. This numerical factor measures the loadproducing effect of a single plumbing fixture of a given kind. I looked at the tables in the 2015 nsp, but where im confused is figuring out where that is calculated. Examples the examples below show the relative ease with which sizing can be accomplished using tables ii and iii. The fixture unit concept is a method of calculating maximum probable water demand within large buildings based on theory of probability. Sizing is based on water supply fixture units wsfu each fixture is assigned a wsfu in the upc. Utilities with meters bill by the unit, normally, such units are measured as 100. Fixture unit allowance table based on allowable friction loss and pipe diameter for type l. Example i have a 34 supply line that tees to two 12 branches.
Water supply fixture units wsfu for typical nonpotable applications. The meaning of wfu abbreviation is water fixture units. These can be in the supplemental documents if you so choose. This figure is used to design main pipes and tanks serving at least 200 to 500 households. Fixture unit computations computing fixture units is a fundamental element of sizing piping systems for water distribution and drainage. Fixture unit allowance table based on allowable friction loss and pipe diameter for type l copper pipe tabulated based on charts a 2. This conversion can only be used for one or a few fixtures.
Obtain available local information regarding the use of different kinds of pipe with respect both to durability and to decrease in capacity with length of service in the particular water supply. Code section section title description of change 2018 2015. Introduction the current prescribed and accepted methods for sizing of water supply and sanitary drainage pipework for plumbing systems in buildings in australia are based on methods of estimation of. From the tabulated fixture units as shown above, the designer can assign fixture unit values to the specific fixtures of concern in his design. Water supply fixture units may be converted to gallons per minute in accordance with table 382. The maximum water flow rates and flush volume for plumbing fixtures and fixture fittings shall comply with section 604. Fixture unit flow relationship once the total fixture count is obtained, the next step is to correlate this to the probable. This worksheet is to be used for any single family andor adu project where new plumbing fixtures are to be installed \in a new building or an existing building\. Table i allowed distance from fixture trap to vent. Pipe sizing is included for systems below 112 psi and for systems above 112 psi. The separate cold water and hot water fixture unit value for fixtures having both cold and hot water connections may each be taken as threequarters 34 of the listed total value of the fixture.
Fullbath group flush tank 1 tank toilet, 1 bathroom sink and either 1 shower, 1 tub or 1 showertub combination. The first edition was printed in 1975, and the second edition was printed in 2004. Thus, such information should be obtained from responsible parties and appropriate local authorities. The most common shorthand of water fixture units is wfu. Once heated, the hot water must be delivered to the intended point of use in the home. The water supply fixture units wfsu are used to determine the water demand in water supply systems. Values assigned to specific types of fixtures are crucial in the sizing of a plumbing system. Press shift question mark to access a list of keyboard shortcuts.
Appliances, appurtenances, and fixtures not referenced in the table below shall be permitted to be sized by reference to fixtures having a similar flow rate and frequency of use. Oct 19, 2004 in the supplied drawing using the default schedule table it does not read the fixture units from the fixture itself. The data that is on the table is something that was hand written in when applying the tag. For example, if your meter says you used 41 cubic feet in a day, you would multiply 41 by 7.
Uses associated with commercial food processing, preparation, handling, or group. The fixture unit concept is a method of calculating maximum probable water demand. The method is based on assigning a fixture unit fu value to each type of fixture based on its rate of water consumption, on the length of time. Concluding the example, we will assume the restroom has its own vent to the roof with a. The listed fixture unit values represent their total load on the cold water service. Combination fixture this fixture combines the functions of a sink and a toilet into a single fixture and is located in private space. Individual fixtures, minimum fixture branch pipe size, water supply fixture units wsfu. The listed fixture unit values represent their load on the cold water building supply. Fixture count, flow calculations, line and meter size north city water district. Water supply fixture units wsfu a 12 water line of 40 in length can supply 6 wsfu at 3540 psi. Table h horizontal fixture branches and stacks 890. Both hot and cold service water will be needed inside the building.
Fixture outlet individual 3 or more general heavyuse. The wsfu water supply fixture units is defined by the uniform plumbing code upc and can be used to determine water supply to fixtures and their service systems. Sizing of water piping system the provisions contained in this appendix are adopted as part of this code. The residential water fixture unit calculation sheet must be signed and sealed by an engineer licensed in the state of colorado.
Find the number closest to the wsfu value on table e103. The major hot water load in a living unit is shower head consumption. Fixture unit table for determining water pipe and meter sizes. Plumbing fixture units on schedule autodesk community. Main office 2550 sw hillsboro highway hillsboro, oregon 97123 p. Assume that the highest fixture supply outlet is 20 ft 6. The difference in elevation can result in an increase or decrease in availablepressure atthe main. The fixture unit concept is a method of calculating maximum probable water demand within. I recognize that t typical a plumbing system is designed to serve only 1015 percent of the total connected fixture load under simultaneous use. Each fixture has its own singular loading effect on the system, which is determined by the rate of water supply required, the duration of each use, and the frequency of use.
Length of piping between the water heater and a given fixture. Review and approval of wsfu and riser diagram will be in projectdox by dc. This information along with other submittals and documents for your project will assist the. Water supply fixture units worksheet msw4 small existing service 2inch and smaller diameter existing water service is classified as a small existing service.
Converting water supply fixture units wsfu to gallons. Learn vocabulary, terms, and more with flashcards, games, and other study tools. Currently, more is known and understood about general water demand patterns and peak demands because of the increasing focus on demand management in the water industry. Water supply fixture units wsfu and minimum fixture branch pipe sizes.
Water supply fixture unit form water demand worksheet 2016. The maximum fixture loading limit for a 12 line under the upc is generally recognized as 4 fixture units meaning you are woefully undersized for the number of fixture units calculated. Appendix b sizing the building water supply and distribution. Table n water supply fixture units wsfu for a supply system with flush tanks water closets. Water supply fixture units wsfu for typical nonpotable. Water supply fixture units wsfu engineering toolbox.